TUV Test Report for BONOSS Wheel Extended Bolts Neutral Salt Spray Test 192 Hours (No: 01 220 CHN/T-1905443)

By |2020-01-12T02:58:48+00:00January 12th, 2020|Extended Wheel Bolts Test, TÜV Certification, TÜV Neutral Salt Spray Test|

TUV Test Report for BONOSS Wheel Extended Bolts Neutral Salt Spray Test 192 Hours No: 01 220 CHN/T-1905443 Test Method: ISO 9227:2017 Concentration of solution collected: (50±5) g/L NaCl Chamber temperature: (35±2) ℃

TUV Test Report for BONOSS Wheel Bolts M14x1.25 Neutral Salt Spray Test 192 Hours (No: 01 220 CHN/T-1905442)

By |2020-01-12T02:52:26+00:00January 12th, 2020|TÜV Certification, TÜV Neutral Salt Spray Test, Wheel Bolts Test|

TUV Test Report for BONOSS Wheel Bolts M14x1.25 Neutral Salt Spray Test 192 Hours No: 01 220 CHN/T-1905442 Test Method: ISO 9227:2017 Concentration of solution collected: (50±5) g/L NaCl Chamber temperature: (35±2) ℃

TUV Test Report for BONOSS Wheel Bolts M14x1.5 Neutral Salt Spray Test 192 Hours (No: 01 220 CHN/T-1905441)

By |2020-01-12T02:49:14+00:00January 12th, 2020|TÜV Certification, TÜV Neutral Salt Spray Test, Wheel Bolts Test|

TUV Test Report for BONOSS Wheel Bolts M14x1.5 Neutral Salt Spray Test 192 Hours No: 01 220 CHN/T-1905441 Test Method: ISO 9227:2017 Concentration of solution collected: (50±5) g/L NaCl Chamber temperature: (35±2) ℃